Fire Protection Inside Electrical Panels: Why Not Water?

Fire Protection Inside Electrical Panels: Why Not Water?

Rasnal TelecomSecurity
Rasnal TelecomSecurity
8 min read

An electrical panel is one of the most important boxes in any building. It is also one of the most likely places for a small fault to turn into a fire: a loose connection, an overloaded circuit, an ageing component. And panels are often closed, live and unattended.

So what should protect them? Not water.

 

How Fires Start Inside Panels

 

Most panel fires do not begin with a dramatic event. They start small and build up:

  • Loose connections that heat up under load
  • Overloaded circuits that run hot for months
  • Ageing insulation that cracks and arcs
  • Dust and moisture that create leakage paths
  • Faulty components in drives, chargers and battery systems

Because panels are closed, the early stage is invisible. By the time smoke shows outside, the damage inside is serious. That is why protection must work from inside the enclosure.

 

Fire Protection Inside Electrical Panels: Why Not Water?

Why Water Is the Wrong Tool for a Live Panel

  • Water can conduct electricity. Spraying a live panel can cause short circuits and more damage, and it is a shock risk for anyone close by.
  • A sprinkler protects the room, not the panel. Sprinkler heads sit at the ceiling and react to room heat. A fire inside a closed cabinet may burn for a while before enough heat reaches them.
  • Water spreads the damage. Neighbouring panels, racks and cables get wet even if they were never on fire.
  •  

None of this is an argument against sprinklers in a building. They have a job. But for the inside of a live panel, you need something made for that space.

 

What About CO2?

 

CO2 does not conduct electricity, and trained people use it on electrical fires. The issue is not the gas. It is the way it is delivered.

  • A hand-held CO2 extinguisher needs a person on the spot. Many electrical rooms and cabinets are unattended, especially at night.
  • A piped CO2 flooding system works without a person, but it needs cylinders, pipes, release controls and a sealed room. That is a lot of equipment for one panel.

Enter the Aerosol Fire Suppression Device

 

An aerosol fire suppression device is a small, self-contained unit that you fit inside an enclosed electrical space. A heat-sensitive trigger wire sets it off when the heat inside the enclosure reaches a set level. It then releases aerosol that fills the enclosure and suppresses the fire.

The key points are that it works by itself, needs no power supply, and needs no wiring. So it can still act if the panel loses power during a fault.

 

Example: Rasnal's HAFED

 

Rasnal's Heat Aerosol Fire Extinguishing Device, or HAFED, is one example of this approach. According to the product page:

 

  • It activates automatically through a heat-sensitive triggering wire
  • It mounts with industrial adhesive, with no wiring needed
  • Its service life is up to 10 years with no maintenance
  • Its operating temperature range is -50°C to +90°C
  • It is certified to the European standards EN 15276-1:2019 and EN 15276-2:2019
  • It comes in two sizes: HAFED-28 for standard panels, distribution boards, battery packs and control cabinets, and HAFED-07 for compact spaces such as MCB boxes, server enclosures and engine bays

Comparing the Options

OptionSafe on live gearWorks without a personNeeds piping or powerFits inside a panel
Water / standard sprinklerNoYes (room level)Water pipeworkNo, protects the room
Hand-held CO2 extinguisherDoes not conduct; used by trained peopleNoNoNo, used from outside
Piped CO2 flooding systemDoes not conductYes, with detection and release controlsCylinders, pipes, controlsNo, protects a room or zone
Heat aerosol deviceMaker states it does not conductYes, heat-triggeredNo wiring, no power supplyYes, made for enclosures

Where These Devices Fit

 

Inside enclosed spaces such as:

  • Electrical panels and distribution boards
  • MCB boxes and server enclosures
  • Telecom, CCTV and industrial control boxes
  • Inverter cabinets and energy storage units
  • Lithium-ion battery packs
  • EV chargers

 

Planning the Installation

 

A few points help you get it right.

  • Fit it inside the enclosure. The device is made for a closed panel, cabinet or box.
  • Leave clearance. The HAFED page lists thermal clearance figures: 0.3 m at 75°C or less, 0.12 m at 200°C or less, and 0.05 m at 400°C or less. In simple terms, the closer to the unit during a discharge, the hotter it gets, so keep heat-sensitive parts away.
  • Choose the right size. A standard enclosure suits the larger unit. A tight space suits the compact one.
  • Follow the installation instructions and ask the supplier where the unit and its trigger wire should sit in your panel.
  • Record the fitting date so you can plan the replacement at end of life.

 

What They Do Not Do

 

Be realistic about the limits.

  • They protect the enclosure they sit in. They do not replace room-level protection. Your building may still need other systems, and your fire officer or insurer may set requirements.
  • They stop a fire. They do not prevent a fault. Good maintenance, correct wiring and surge protection reduce the chance of a fire starting.
  • They are replaced after use. Once a unit activates, or when it reaches the end of its life, it is replaced.
  • Check the panel after a discharge. A qualified electrician should inspect the equipment before it goes back into service. Ask the manufacturer for data on residue and clean-up.

 

Questions to Ask a Supplier

 

  1. Which standard is it certified to?
  2. How is it triggered, and does it need power?
  3. How is it mounted, and what clearance does it need around it?
  4. What is the service life, and when must it be replaced?
  5. Which size suits my enclosure?

 

The Takeaway

 

For the inside of a live panel, think small, automatic and self-contained. Water and standard sprinklers are the wrong match. A heat-triggered aerosol device fits the enclosure, works without power and does not need wiring.