How Much Clearance Should You Leave Between Pallets and Racking Beams?

Pallet Racking Clearance: Gaps, Flue Space and Beam Length

Getting pallet racking clearance right is a balance. If there is not enough space between pallets and the uprights, the uprights can be damaged, pallets can jam and the sprinklers may not work properly. If there is too much space, valuable warehouse storage is wasted. By leaving the right spacing between pallets in your warehouse racking, more pallets can be stored quickly, safely and efficiently. Below is the correct amount of space to leave between pallets, and why.

Horizontal Spacing

In standard pallet racking systems, leave approximately 75 mm between the pallets and the uprights, and 100 mm between pallets placed side by side. This gives the forklift room to place and lift the pallets without damaging either the pallets or the racking. If the gap is too small, pallets become hard to place. At height, even a few centimetres of pallet movement can cause significant problems.

Vertical Spacing

Leave around 75–100 mm of vertical clearance between the top of the load and the underside of the racking beam above. This lets pallets go in smoothly without striking the racking beams. With too little clearance, pallets are hard to put away. With too much, you can lose a whole storage level over the height of the racking.

Infographic: 75 mm gaps at uprights, 100 mm between pallets, 75–100 mm under the beam, a 2,250 mm beam for two 1,000 mm pallets, and transverse vs longitudinal flue spaces

Flue Space

Racking must include flue spaces to meet fire safety requirements. The transverse flue is the vertical gap between loads standing side by side in the same row, including the gaps at the uprights. The longitudinal flue is the vertical gap between back-to-back rows. These flues let sprinkler water reach the seat of a fire, and let heat and smoke rise to set off the sprinkler heads. Fire codes commonly call for a longitudinal flue of around 150 mm; transverse flue sizes depend on the code and the sprinkler design. If overhanging or oversized loads block these spaces, the sprinkler system may not work in an emergency. Keeping flue spaces clear is a safety requirement.

Calculating Beam Lengths

To size a rack bay, add up the pallet widths and the gaps. Two pallets 1,000 mm wide take up 2,000 mm. Add the two 75 mm gaps at the uprights and the 100 mm gap between the pallets, and you need a beam of approximately 2,250 mm. Then choose the next standard beam length above this figure. A third pallet adds one more pallet width and one more internal gap, giving approximately 3,350 mm. Always use the actual pallet width, which depends on the pallet size and which way it is loaded, and check that the beam is rated for the total weight.

Pallet Racking Clearance: Summary

As a rule of thumb, leave 75 mm between pallets and racking uprights, 100 mm between pallets and 75–100 mm between the top of the load and the beam above, and keep flue spaces of around 150 mm clear. This lets pallets be placed into the racking quickly, protects stock and staff, and makes efficient use of space. Incorrect spacing can damage the racking structure, slow down put-away and stop the fire suppression system from reaching a fire.

Frequently Asked Questions

How much space should be left between pallets?

Generally, leave 100 mm between two pallets and 75 mm between the pallets and the racking uprights. Leave approximately 75–100 mm of vertical space between the top of the load and the beam above, so pallets can be placed and removed easily without hitting the racking or the next load.

Why is a flue space required?

Flue spaces between pallets and between rows are needed for the sprinkler system to work. Transverse flues are the vertical gaps between loads side by side in the same row, and longitudinal flues are the vertical gaps between back-to-back rows. They let sprinkler water reach the fire directly, and let heat and smoke rise to activate the sprinkler heads. Fire codes often require around 150 mm of longitudinal flue space. Keeping these spaces clear is essential for effective fire safety.

How do I work out the length of beam required to fit multiple pallets?

Add the widths of all the pallets to the gaps: approximately 75 mm at each upright and approximately 100 mm between pallets. For two 1,000 mm pallets, the beam needs to be 2,000 + 75 + 75 + 100 = approximately 2,250 mm. For three pallets, add one more pallet width and one more internal gap, which gives approximately 3,350 mm. Then select the next standard beam length above this figure and confirm the beam is rated for the weight of all the pallets.