Appropriate care and upkeep of your X-ray equipment supplied by X-Ray Machine Suppliers will help defend your financial investment and help you achieve optimal performance with your equipment. Following are 6 endorsements to maximize the ROI of your imaging equipment and keep it in the best operation, thus obtaining better diagnostic results. 

  1. Complete steady precautionary maintenance
  2. Use and operate gadgets properly
  3. Don’t oversee component care
  4. Operate equipment within its technical stipulations
  5. Deliver the optimum setting for your X-ray equipment
  6. Use only permitted cleaners and decontaminators on the equipment exterior.

Complete steady precautionary maintenance

Precautionary upkeep is critical to help keep your equipment running at peak performance, in acquiescence of all controlling and safety standards, and within the working, standards determined by the X-Ray Machine Manufacturers. Only approved and specialized service personnel must perform work on the equipment.

Many imaging amenities enter into a technical service policy with their manufacturer for three good motives. For one, your supplier’s workers have been specially qualified by the manufacturer and will have the essential tools to carry out the corresponding calibrations. You won’t know needless delays like you might if an outside tech arrives without the proper apparatuses.

There are numerous service plans with different coverage for X-ray equipment upkeep, so it is important to spend some time finding the one that best suits your requirements and budget. You will need to reflect on your use of the system. If you have a heavy volume, your apparatuses will likely erode out faster. Heavy workload also will need more hours of upkeep than lower volume equipment.

One of the most significant and costly components of X-ray machines is the X-ray tube. Make sure your service policy comprises standby of this critical part. Without it, your processes are closed down for the day.

After the upkeep is complete, your service technician must provide you with a detailed service report that lists all the maintenance that was completed.

Use and operate imaging equipment correctly

Correct use and operation of the equipment are key to keeping it working properly. Thus, it is significant to keep your staff qualified in its use. Training settings are usually presented by your X-ray Machine Dealers

Don’t ignore constituent care

The care and upkeep of components are often ignored. Though, they are also significant to the full functioning of your system. Their stoppage would negatively influence the ROI of your imaging equipment. Apparatuses include batteries, radiographic films, phosphor frames, and sensors. Here are some endorsements that will help you keep your apparatuses in good condition and help deliver the best image quality.

Sensors are mission-critical apparatus. A broken DR sensor can bring your modernized workflow to a halt. Care also must be taken to cut the probability of harm to the sensors from fluids and chemicals. Use plastic bags in circumstances where the detectors might be unprotected from liquids and chemicals to minimize problems and damage from filtration.

If you are using a CR structure, the phosphor chassis needs sporadic cleaning of the internal screens. This will decrease the artifacts that can be produced by dust and other elements on the screen. Be sure to use only fluids for cleaning that are suggested by the manufacturer. Also, note that the use of gauze or any other cloth that leaves residues is not suggested since they also can reason artifacts in the images.

And if you are using film, recollect that radiographic films are very subtle so you mustn't store them for an extended time. Check the ending date sporadically. Also, check the cataloging and manufacturer’s references for the appropriate temperature range for storage.

Function equipment within its mechanical specifications

Knowing the mechanical stipulations of your equipment will deliver valuable information on the capabilities of your system. For instance, you don’t want to abuse your low-volume equipment. Low-volume equipment may process information rapidly, but it was intended for a certain level of patient volume. Appropriate use of the equipment will permit you to considerably reduce the amount of corrective maintenance. You can find your equipment’s mechanical specifications in the user guide you received with the equipment.

You also must continually assess equipment usage against its practical specifications. Keeping track of your volume and observing any variations will be valuable to you when it is time to purchase new equipment.

Deliver the best environment for your X-ray equipment

Another issue for X-ray equipment upkeep is the operating environment. Continuously keep your apparatus at the appropriate temperature. You can find the operational temperature suggested by the manufacturer in your operation manual.

You also require a decent electrical system. Electrical glitches that suddenly disturb the operation of the equipment can cause damage to the application or programs that keep your equipment running. To help evade this, reach out sporadically to the appropriate person in your facility for periodic maintenance of your electrical network.

Use only accepted antiseptics and cleaners on equipment exterior

It also is significant to keep your gear in good physical appearance. You may not think that this influences equipment performance, but it does. X-ray equipment that is clean and free of any obvious dirt or staining is more comforting to patients, especially for surface safety.

The cleaning must focus on the exterior of the equipment: the shelters and command and display controls (if armed with your equipment). Use only the actions and the chemical mixtures authorized by the manufacturer. The use of unsanctioned cleaning solutions may reason discoloration. Also, a poor cleaning procedure may result in chemical leakage on user interaction screens and impact their use. Consult your operation guide for more recommendations. If cleaning actions are not stated or you no longer have your manual, contact your X-ray Machine suppliers. It also is significant to turn X-ray equipment off before doing any scrubbing to avoid electrical damage.